Frequent ERRORS in implementing ETICS

  • base rendering thickness incorrect (layer thickness as per ÖNORM B 6410:Table 6 [OEN11a])
  • damage caused by insulation panels shrinking
  • insulation panels not anchored properly
  • top rendering not thick enough
  • faulty execution of connections at dado level
  • substantial gaps between insulation panels not plugged with foam
  • minimum width of offcuts not kept to, joints not offset correctly, no diagonal reinforcement at windows
  • defects involving base rendering, execution of joints, distribution and insertion of dowels