01 02 03 04 05 06 07
Frequent Errors in implementing ETICS
Frequent ERRORS in implementing ETICS
- base rendering thickness incorrect (layer thickness as per ÖNORM B 6410:Table 6 [OEN11a])
- damage caused by insulation panels shrinking
- insulation panels not anchored properly
- top rendering not thick enough
- faulty execution of connections at dado level
- substantial gaps between insulation panels not plugged with foam
- minimum width of offcuts not kept to, joints not offset correctly, no diagonal reinforcement at windows
- defects involving base rendering, execution of joints, distribution and insertion of dowels
(source: http://www.schoeberlpoell.at/download/forschung/endbericht_sanierungshandbuch.pdf)